Draeger 8101521 Gas Detector Tube, Phosgene 0.02/a, 10/Box

Draeger 8101521 Gas Detector Tube, Phosgene 0.02/a, 10/Box
Dräger
SKU:
DRA8101521
$167.19
/ Box
Weight:
1.50 LBS
Adding to cart… The item has been added

Draeger 8101521 Gas Detector Tube for phosgene provides a simple, time‑tested method for measuring phosgene concentrations in air using a portable Draeger tube pump. This glass tube is designed for single‑use, break‑off tip operation, and includes a designated measurement range to indicate phosgene levels from 0.02 up to 1 ppm (with a sub‑range of 0.02 to 0.6 ppm) over a fixed test duration of either 6 or 12 minutes, depending on the specific tube plotting. Packaged as a box containing ten tubes, it is intended for field or bench testing where phosgene monitoring is required in industrial settings. The tube’s glass construction and break‑off tip are standard features for easy handling and waste containment after use, supporting straightforward sampling workflows when paired with a compatible Draeger tube pump.

The product is configured specifically to detect phosgene at the stated concentration ranges, enabling operators to perform colorimetric or color‑change interpretations as the reaction occurs along the tube’s length under dry, ambient air conditions. Because the precise ranges and test times are built into the tube’s chemistry, users should align measurement expectations with the corresponding pump settings and follow established sampling procedures to ensure data accuracy. This item is suitable for applications where quick, qualitative to semi‑quantitative phosgene assessment is needed under routine monitoring practices.

Compatibility is defined by the Draeger tube system: use these tubes with a Draeger tube pump and appropriate accessories designed for phosgene analysis. Each box contains ten tubes, supporting medium‑volume testing requirements in laboratory, production floor, or safety compliance workflows where phosgene exposure risk assessment is routine. Dispose of used tubes per local waste handling guidelines after measurement is completed.

Features:

  • Phosgene detection using 0.02/a specification
  • Standard measurement ranges: 0.02-1 ppm and 0.02-0.6 ppm
  • Measurement time options: 6 minutes or 12 minutes
  • Glass tube with break-off tip for safe sampling
  • Box quantity: 10 tubes per box
  • Specific to phosgene gas monitoring

Gas Detected:
Phosgene 0.02/a
Standard Range Of Measurement:
0.02 - 1 ppm, 0.02 - 0.6 ppm
Measurement Time:
6 Min, 12 Min
Tube Material:
Glass
Break-Off Tip:
Yes
Package Size:
Box
Box Quantity:
10/Box